Decription:
Single-pole breakaway in-line fuse holders for any 13/32" x 11/2" fuses. Typically fuse types: BAF, DCM, FNM, FNQ, and KTK.
Ratings:
Features and Benefits:
@ Breakaway and non-breakaway, in line fuse holders used with supplementary fuses in below ground junction boxes and pole bases for lighting circuit protection.
@ Provides a variety of breakaway and non-breakaway configurations to meet street and area lighting requirements.
@ Provides a variety of breakaway and non-breakaway configurations to meet street and area lighting requirements.
Typical Applications:
@ Pole-Mounted Lighting Systems
@ High Bay Mounted Lighting Systems
@ Multiple String Lighting Systems
@ High Bay Mounted Lighting Systems
@ Multiple String Lighting Systems
Note:
(1) UL Recognized, Guide IZLT2, File E14853
(2) CSA Certified, Class 6225-01, File 47235
(3) CE
For custom terminations contact your Cooper Bussmann representative.
To select complete holder P/N, work from left to right starting with load terminal options and then determine breakaway or non-breakaway style.
(2) CSA Certified, Class 6225-01, File 47235
(3) CE
For custom terminations contact your Cooper Bussmann representative.
To select complete holder P/N, work from left to right starting with load terminal options and then determine breakaway or non-breakaway style.
Data Sheet:
Catalog Number | Loadside Terminal-Terminal Type | Loadside Terminal-Wire Size | Loadside Terminal-No. of Wires per Terminal |
Loadside Terminal-Solid Wire | Loadside Terminal-Stranded Wire | Lineside Terminal-Terminal Type | Lineside Terminal-Wire Size | Lineside Terminal-No. of Wires per Terminal |
Lineside Terminal-Solid Wire | Lineside Terminal-Stranded Wire | Load Terminal-Terminal Type | Load Terminal-Wire Size | Load Terminal-No. of Wires per Terminal |
Load Terminal-Solid Wire | Load Terminal-Stranded Wire | Line Terminal-Terminal Type | Line Terminal-Wire Size | Line Terminal-No. of Wires per Terminal |
Line Terminal-Solid Wire | Note |
HEB-AW-RLC-A(1)(2)(3) | Copper Crimp |
#12 to #8 #12 |
1 2 |
Y Y |
Y Y |
Copper Crimp |
#12 to #8 #12 |
1 2 |
Y Y |
Y Y |
Breakaway ((Boots included) | |||||||||
HEB-AW-RLC-B | Y Y |
Copper Crimp |
#12 to #8 #12 |
1 2 |
Y Y |
Y Y |
Copper Crimp |
Y Y |
1 2 |
Y Y |
Breakaway ((Boots included) | |||||||||
HEB-AW-RLC-C(4) | Y Y |
Copper Crimp |
#12 to #8 #12 |
1 2 |
Y Y |
Y Y |
Copper Crimp |
#4 #8 |
1 2 |
N Y |
Breakaway ((Boots included)(4) HEB-AW-RLC-C is for (1) #4 stranded wire only. | |||||||||
HEB-AW-RLC-J | Y | Copper Crimp |
#12 to #8 #12 |
1 2 |
Y Y |
Y Y |
Copper Setscrew |
#12 to #3 |
1 |
Y |
Breakaway ((Boots included) | |||||||||
HEB-AW-RYC | Y | Copper Crimp |
#12 to #8 #12 |
1 2 |
Y Y |
Y Y |
Copper Setscrew |
#12 to #3 |
2 | Y |
Breakaway ((Boots included) | |||||||||
HEB-AW-RLA | Y | Copper Crimp |
#12 to #8 #12 |
1 2 |
Y Y |
Y Y |
Aluminum Setscrew |
#12 to #2 |
1 |
Y |
Breakaway ((Boots included) | |||||||||
HEB-AW-RYA | Y | Copper Crimp |
#12 to #8 #12 |
1 2 |
Y Y |
Y Y |
Aluminum Setscrew |
#12 to #2 |
2 | Y |
Breakaway ((Boots included) | |||||||||
HEB-BW-RLC-A | Y Y |
Copper Crimp |
#6 #10 |
1 2 |
Y Y |
Y Y |
Copper Crimp |
#12 to #8 #12 |
1 2 |
Y Y |
Breakaway ((Boots included) | |||||||||
HEB-BW-RLC-B | Y Y |
Copper Crimp |
#6 #10 |
1 2 |
Y Y |
Y Y |
Copper Crimp |
#6 #10 |
1 2 |
Y Y |
Breakaway ((Boots included) | |||||||||
HEB-JW-RLC-J | Y | Copper Setscrew |
#12 to #3 | 1 |
Y |
Y |
Copper Setscrew |
#12 to #3 |
1 |
Y |
Breakaway ((Boots included) | |||||||||
HEB-JW-RYC | Y | Copper Setscrew |
#12 to #3 | 1 |
Y |
Y |
Copper Setscrew |
#12 to #3 |
2 | Y |
Breakaway ((Boots included) | |||||||||
HEB-LW-RLA | Y | Aluminum Setscrew |
#12 to #2 | 1 |
Y |
Y |
Aluminum Setscrew |
#12 to #2 |
1 |
Y |
Breakaway ((Boots included) |