E-rated fuses,CL-14,ECL055

Medium Voltage Fuses and Fuse Links
E-rated fuses,
CL-14


ECL055
Specifications
Decription:
E-rated medium voltage, current-limiting fuses for transformer and feeder protection.
Construction:
Filament wound, glass epoxy fuse tube, with silica filler, and silver-plated copper terminals and endcaps containing a silver element in a double concentric helical
configuration.
Ratings:
Volts:- 5.5 kV
Amps:- 10-900A
IR:- 63kA Sym. Max
Agency Information:
Meets E requirements per ANSI C37.46, Meets General Purpose requirements per ANSI C37.40.
Features and Benefits:
@ Clip-lock style available in double and triple barrel fuse designs for application flexibility
@ The filament wound, glass epoxy fuse tube provides UV and moisture protection, making these medium voltage fuses suitable for both indoor and outdoor applications
@ Open fuse indication (indicator travel distance is 16mm)
easily integrates into automation schemes
@ 50/60 Hz operating frequency make these fuses applicable world-wide
Typical Applications:
@ 5.0 kV Transformer Primary Protection
@ 5.0 kV Feeder Circuit Protection
@ 5.0 kV Voltage Switches
@ 5.0 kV Metal-enclosed Switchgear
Note:
Current-limiting medium voltage fuses are
classified into three categories:
1. Full Range - defined by ANSI as ia fuse capable of
interrupting all currents from the maximum rated interrupting current down to the minimum continuous current that causes melting of the fusible element(s), when the fuse is applied at the maximum ambient temperature specified by the
manufacturer.@ It is able to interrupt any normal 60 cycle
current that will melt its element.
2. General Purpose - defined by ANSI C37.40 as ia fuse capable of interrupting all currents from the maximum rated interrupting current down to the current that causes melting of the fusible element in one hour.@ Not all currents fall within this range. It is possible to receive an overcurrent lower than the value given by the one hour criterion.
3. Back-up - defined by ANSI C37.40 as ia fuse capable of interrupting all currents from the maximum rated interrupting current down to the rated minimum interrupting current.@ The minimum rated interrupting current is the lowest current that the fuse will be able to clear properly. This creates a need to place a low current interrupting device in series with the back-up rated fuse.
Catalog Number Construction (Example):
Catalog Number Voltage Rating Ampere Rating
ECL 055 500E
055 = 5.5 kV
Data Sheet:
Catalog Number Amp Rating Voltage IR Max Sym. # of Barrels Style Ferraz-Shawmut New Catalog # Ferraz-Shawmut Old Catalog #
ECL055-10E 10 5.5kV 63kA 1 Clip-Lock A055C1DORO-10E 225-007-937
ECL055-15E 15 5.5kV 63kA 1 Clip-Lock A055C1DORO-15E 225-007-938
ECL055-20E 20 5.5kV 63kA 1 Clip-Lock A055C1DORO-20E 225-007-939
ECL055-25E 25 5.5kV 63kA 1 Clip-Lock A055C1DORO-25E 225-007-940
ECL055-30E 30 5.5kV 63kA 1 Clip-Lock A055C1DORO-30E 225-007-941
ECL055-40E 40 5.5kV 63kA 1 Clip-Lock A055C1DORO-40E 225-007-942
ECL055-50E 50 5.5kV 63kA 1 Clip-Lock A055C1DORO-50E 225-007-943
ECL055-65E 65 5.5kV 63kA 1 Clip-Lock A055C1DORO-65E 225-007-944
ECL055-80E 80 5.5kV 63kA 1 Clip-Lock A055C1DORO-80E 225-007-945
ECL055-100E 100 5.5kV 63kA 1 Clip-Lock A055C1DORO-100E 225-007-946
ECL055-125E 125 5.5kV 63kA 1 Clip-Lock A055C1DORO-125E 225-007-947
ECL055-150E 150 5.5kV 63kA 1 Clip-Lock A055C1DORO-150E 225-007-948
ECL055-200E 200 5.5kV 63kA 1 Clip-Lock A055C1DORO-200E 225-007-949
ECL055-250E 250 5.5kV 63kA 1 Clip-Lock A055C1DORO-250E 225-007-950
ECL055-300E 300 5.5kV 63kA 2 Clip-Lock A055C1DORO-300E 225-007-951
ECL055-400E 400 5.5kV 63kA 2 Clip-Lock A055C1DORO-400E 225-007-952
ECL055-500E 500 5.5kV 63kA 2 Clip-Lock A055C2DORO-500E 225-007-954
ECL055-600E 600 5.5kV 63kA 2 Clip-Lock A055C2DORO-600E 225-007-955