One-time general purpose fuses,NON (250Vac/125Vdc) Class K5 & H


 

NON (250Vac/125Vdc) Class K5 & H
Specifications
Decription:
General purpose, non-current-limiting fuses.
Ratings:
Volts- NON:
 - 250Vac
 - 125Vdc (0-100A)
 - NOS:
 - 600Vac
Amps- 1/8-600A
IR- 50,000A RMS Sym. (NON & NOS Class K5
 0-60A)
 - 10,000A RMS Sym. (NON & NOS Class H
 65-600A)
 - 50,000A @ 125Vdc (NON Class K5 0-60A)
 - 10,000A @ 125Vdc (NON Class H 65-100A)
Agency Information:
CE, UL Listed n 250V: Class K5
(0-60A), Std. 248-9, Class H (65-600A), Std. 248-6, (125Vdc: NON 0-100), 600V: Class K5 (0-60A), Std. 248-9, Class H (70-600A), Std. 248-6, Guide JDDZ, File E4273, CSA Certified n 250V: (0-12, 65-600)U, 600V: (0-600), Class 1421-01, File 53787.
U For CSA Certified 15-60A Ratings, see PON Data Sheet 4126
Features and Benefits:
@ Original fuse providing circuit protection.
Typical Applications:
@ Light Duty Circuit Locations
Note:
For superior electrical protection, Cooper Bussmann recommends upgrading NON (250Vac) and NOS (600Vac) fuse applications to Low-Peak LPN-RK (250Vac) and LPS-RK (600Vac) fuses.
Data Sheet:
Catalog Number Amps A B Fuse Reducer - Clip Amp Size Fuse Reducer - Catalog No. (Pairs) Note
NON-1/8 1/8 2 (50.8) 0.56 (14.3) 100 213 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-1/2 1/2 2 (50.8) 0.56 (14.3) 100 213 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-3/4 3/4 2 (50.8) 0.56 (14.3) 100 213 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-8/10 8/10 2 (50.8) 0.56 (14.3) 100 213 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-1 1 2 (50.8) 0.56 (14.3) 100 213 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-1 1/4 1 1/4 2 (50.8) 0.56 (14.3) 100 213 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-1 1/2 1 1/2 2 (50.8) 0.56 (14.3) 100 213 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-1 6/10 1 6/10 2 (50.8) 0.56 (14.3) 100 213 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-2 2 2 (50.8) 0.56 (14.3) 100 213 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-2 1/2 2 1/2 2 (50.8) 0.56 (14.3) 100 213 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-3 3 2 (50.8) 0.56 (14.3) 100 213 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-3 2/10 3 2/10 2 (50.8) 0.56 (14.3) 100 213 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-4 4 2 (50.8) 0.56 (14.3) 100 213 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-5 5 2 (50.8) 0.56 (14.3) 100 213 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-6 6 2 (50.8) 0.56 (14.3) 100 213 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-6 1/4 6 1/4 2 (50.8) 0.56 (14.3) 100 213 CLASS RK1 & RK5 Dimension - in
(mm)

Basic dimensions are
same as Class H (formerly NEC)
One-Time (NON & NOS) and Superlag
Renewable RES & REN fuses. NOTE:
These fuses can be used to replace
existing Class H, RK1 and RK5 fuses
relating to dimensional compatibility.
NON-7 7 2 (50.8) 0.56 (14.3) 100 213 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-8 8 2 (50.8) 0.56 (14.3) 100 213 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-9 9 2 (50.8) 0.56 (14.3) 100 213 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-10 10 2 (50.8) 0.56 (14.3) 100 213 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-12 12 2 (50.8) 0.56 (14.3) 100 213 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-15 15 2 (50.8) 0.56 (14.3) 100 213 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-20 20 2 (50.8) 0.56 (14.3) 100 213 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-25 25 2 (50.8) 0.56 (14.3) 100 213 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-30 30 2 (50.8) 0.56 (14.3) 100 213 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-35 35 3 (76.2) 0.81 (20.6) 200 226 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-40 40 3 (76.2) 0.81 (20.6) 200 226 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-45 45 3 (76.2) 0.81 (20.6) 200 226 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-50 50 3 (76.2) 0.81 (20.6) 200 226 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-60 60 3 (76.2) 0.81 (20.6) 200 226 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-65 65 5.88 (149.2) 1.06 (26.9) 600 2661 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-70 70 5.88 (149.2) 1.06 (26.9) 600 2661 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-75 75 5.88 (149.2) 1.06 (26.9) 600 2661 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-80 80 5.88 (149.2) 1.06 (26.9) 600 2661 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-90 90 5.88 (149.2) 1.06 (26.9) 600 2661 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-100 100 5.88 (149.2) 1.06 (26.9) 600 2661 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-110 110 7.13 (181.0) 1.56 (39.6) 600 2661 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-125 125 7.13 (181.0) 1.56 (39.6) 600 2661 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-150 150 7.13 (181.0) 1.56 (39.6) 600 2661 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-175 175 7.13 (181.0) 1.56 (39.6) 600 2661 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-200 200 7.13 (181.0) 1.56 (39.6) 600 2661 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-225 225 8.63 (219.1) 2.06 (52.3) 600 2664 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-250 250 8.63 (219.1) 2.06 (52.3) 600 2664 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-300 300 8.63 (219.1) 2.06 (52.3) 600 2664 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-350 350 8.63 (219.1) 2.06 (52.3) 600 2664 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-400 400 8.63 (219.1) 2.06 (52.3) 600 2664 Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-450 450 10.38 (263.5) 2.59 (65.8)     Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-500 500 10.38 (263.5) 2.59 (65.8)     Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.
NON-600 600 10.38 (263.5) 2.59 (65.8)     Dimension - in (mm)

Basic
dimensions are same as Class H
(formerly NEC) One-Time (NON &
NOS) and Superlag Renewable RES
& REN fuses. NOTE: These fuses
can be used to replace existing
Class H, RK1 and RK5 fuses relating
to dimensional compatibility.